SK-950C Visual Field Analyzer

Introducing the new SK-950C Visual Field Analyzer, an automated optical perimeter that has full compliance with the Goldman Standard. With perfect, comprehensive monitoring design and accurate detection of the tester cooperation condition, the SK-950C ensures reliable reports for eye care professionals. Perform the most comprehensive exam with multitude of visual field testing options.
SK-950C offers brightness measuring, standard brightness control and auto-calibration. Eye playback, 3D fixation monitoring, gaze tracking, and trial lens frame with infrared projection point. Users can expect precise and rapid medical strategy designed to take full consideration of different age groups, responsiveness, visual field defects, and distribution of field island.
See the full line of diagnostic equipment offered by Coburn Technologies.
STANDARD OPTICAL DESIGN
Built with an optical design system to ensure the projection stimulus is fully compliant with the international standards on every aspect.
Brightness Measuring & Auto-Calibration

Self-check when the perimeter is powered on, adjusting brightness to make sure the initial projection brightness is in standard range.
Stable Light Source

Single light source design with PWM technology to control the original brightness, resulting in more stable light and color temperature.
Standard Brightness Control

The perimeter uses two optical coating films allowing the transmittance level to change, by combining their positions to obtain the 0-51db standard spot brightness. This controls the spot color using a standard color filter ensuring that the spot color temperature accurately stimulates specific cone cells.
RELIABILITY OF THE REPORT
Perfect, comprehensive monitoring design, accurate detection of the tester cooperation condition to ensure the reliability of the report.
3-Dimensional Fixation Monitoring

Using automated optical focusing, infrared light is projected from three directions, X-Y-Z, to the pupil, and if the pupil position changes up/down, left/right, or forward/backward, it can be automatically tracked.
Trial lens frame with infrared projection point

3-D monitoring is also possible when using frames.
Head Tracking

This accurately determines the head position before and after distance change. If the head is out of range, an alarm pops timely.
Gaze Tracking

The computer can adjust the chin rest to track pupil movement, and significantly eliminate the interference due to patient gaze displacement.
PRECISE & RAPID MEDICAL STRATEGY
Inspection strategy designed to take full consideration of different age groups, responsiveness, visual field defects, and distribution of filed island.

COMPREHENSIVE INSPECTION PROCESS
Threshold Test Procedures: | Macula, 10-2, 24-2, 30-2, 60-4, nasal ladder | |
---|---|---|
All Threshold Detection Procedures: | C40, C64, C67, C80, C88, P60, nasal ladder, FF81, FF120, FF135, FF246, FF102 | |
Special Detection Procedures: | Driver field test, driver monocular, driver binocular, upper half 36, upper half 64, blue and yellow detection |
Kinetic

Standard programs, static procedures, dark procedures, blind spot procedures, custom kinetic. Stimulation speed 1-9 degrees/s adjustable.
SWAPÂ

Through the optical lens to obtain the standard color temperature spot and background light. Accurately simulate the blue cone cells to help doctors accurately check the early glaucoma.